Skip to main content

Water Heater Parts Explorer

The standard Southwest Florida setup: an electric tank in the garage or closet with two elements behind the front panels. Tap a part to see what it does, the signs it is going bad, and the replacement we stock.

Loading 3D model…
Drag to spin · pinch or scroll to zoom · tap a partDrag · pinch · tap a part

X-ray

What’s going on?

No hot water
Runs out of hot water fast
Lukewarm water only
Rotten-egg smell
Leaking from the T&P valve
Leaking at the bottom
Popping or rumbling

All 13 parts

Shop all water heater parts (232)

Tools for the job

Non-contact voltage tester or multimeter
1½" element socket wrench
Screwdrivers (panel screws, thermostat terminals)
1-1/16" socket & breaker bar (anode rod)
Garden hose (draining)
Thread seal tape
Bucket & towel

Not sure which one you need?

Bring the old part into our Cape Coral or Fort Myers store — we’ll match it on the spot. Most repair parts are in stock, or order online for free in-store pickup.


Water Heater parts guide

Tank & Jacket

The glass-lined steel tank inside an insulated metal jacket. 40 and 50 gallon are the common sizes.

Signs it’s failing: Water seeping from the bottom seam; Rust on the jacket or around fittings; 10–12+ years old.

Anode Rod

A magnesium or aluminum rod that corrodes so the tank doesn’t. It screws into the top of the tank.

Signs it’s failing: Rotten-egg smell in the hot water; Rod worn down to the steel core; Rusty hot water.

Upper Heating Element

Heats the top of the tank first, so you get hot water quickly after a draw.

Signs it’s failing: No hot water at all; Lukewarm water only; Breaker trips.

Lower Heating Element

Does most of the heating. It sits in the bottom of the tank where sediment collects.

Signs it’s failing: Hot water runs out fast; Popping or rumbling; Leak around the element gasket.

Thermostats & Access Panels

Two thermostats behind the front panels switch power between the elements. The upper one has the red reset button.

Signs it’s failing: No hot water (reset button tripped); Water too hot; Water never gets hot.

T&P Relief Valve

A safety valve that opens if the tank gets too hot or the pressure too high. It keeps the tank from bursting.

Signs it’s failing: Drips or runs out the discharge pipe; Won’t reseat after testing; Crusted or corroded.

Discharge Pipe

Carries water from the T&P valve down to within 6" of the floor or out to a drain.

Signs it’s failing: Water at the end of the pipe; Missing or too short; Cracked.

Drain Valve

The hose-thread valve at the bottom front, used to flush sediment and drain the tank.

Signs it’s failing: Drips from the spout; Clogged with sediment; Cracked plastic valve.

Dip Tube

A plastic tube under the cold inlet that sends incoming cold water to the bottom of the tank.

Signs it’s failing: Hot water runs out fast; Lukewarm water; White plastic bits in faucet aerators.

Water Heater Connectors

The flexible hot and cold lines from the house piping to the top of the tank.

Signs it’s failing: Drip at a nut; Corroded or green fittings; Kinked line.

Cold Shutoff Valve

The valve on the cold line feeding the tank. Close it before any repair.

Signs it’s failing: Won’t shut off fully; Drips at the handle.

Thermal Expansion Tank

A small tank on the cold line that absorbs the water that expands as it heats.

Signs it’s failing: T&P valve drips after the heater runs; Tank sounds full of water when tapped; Rust at the seam.

Drain Pan

The pan the heater sits in, piped to a drain, so a leak doesn’t ruin the floor or ceiling below.

Signs it’s failing: Water in the pan; Cracked pan; No pan under a closet or attic heater.